Fiber Test Equipment

BL-OTDR5000 OTDR

BL-OTDR5000 OTDR

Type:OTDR

Contact Us

Tel:+86 21 57722935

Skype:+86 17612180002

Whatsapp:+86 17612180002

Commissioner:Amy

 
  • Description
  • Parameter
BL-OTDR5000 Optical Time-domain Reflectometer (OTDR)
 
Brellet Telecom’s BL-OTDR5000 series of handheld optical time-domain reflectometers (OTDRs) are of light weight, small size, simple operation and various functions. BL-OTDR5000 series of OTDRs have a built-in PON power meter for Triple-play live testing. BL-OTDR5000-H high configuration series are assembled with stabilized laser source, power meter and visual fault locator (VFL) modules. They can satisfy all kinds of test requirements on FTTx, WAN and backbone optical networks.

Picture


 

Features
  • Quick startup
  • FTTX in-service testing (Up to1:64 splitter)
  • Built-in PON power meter for Triple-play testing
  • High configuration series include optical light source, optical power meter, visual fault locator (VFL) and Optical Connector Inspector (MCI) modules
  • USB data interface (PC software for batch data processing and report output)
  • Dustproof and shockproof (2-meter drop test) 
  • Light weight, small size, rugged design and simple operation
  • 3.5 inch LCD display
  • Visual link image software (Optional)
 
Applications
  • Optical network installation and troubleshooting
  • Backbone optical network
  • WAN, access network and LAN fiber test

Specifications
Parameters Specification
General Configuration Wavelength2 (±20nm) Dynamic
Range (dB)
Event Dead
Zone (m)
Attenuation Dead Zone (m)
BL-OTDR5000-MA 850/1300 21/24 1.5 5
BL-OTDR5000-S2A 1310/1550 32/30 1.8 5
BL-OTDR5000-S2B 1310/1550 35/34 1.5 5
BL-OTDR5000-S2C 1310/1550 40/38 0.8 4.5
BL-OTDR5000-S2D 1310/1550 45/43 0.8 4.5
BL-OTDR5000-S2E 1310/1550 50/48 0.8 4.5
BL-OTDR5000-S3A 1310/1490/1550 38/37/37 0.8 4.5
BL-OTDR5000-S3B 1310/1550/1625 38/37/37 0.8 4.5
BL-OTDR5000-S1A-PON 1625 37 0.8 4.5
BL-OTDR5000-S3B-PON 1310/1550/1625 38/37/37 0.8 4.5
OTDR Module
Testing Range (km) 0.1/0.3/0.5/1.3/2.5/5/10@850nm 0.1/0.3/0.5/1.3/2.5/5/10/20/40/80@1300nm 0.3/1.3/2.5/5/10/20/40/80/120/160/240@others
Pulse Width (ns) 10/30/100/300/1000@850nm
10/30/100/300/1000/2500@1300nm
5/10/30/100/300/1000/2500/10000/20000@others
Testing Time (s) 15/30/60/120/180
Distance Measure Accuracy ±(1m + 5×10‑5 ×distance + sampling space)
Linearity (dB) ±0.05
Reflection Detect Accuracy (dB) ±4
Data Storage 1000 records
Connectivity USB
Optical Port FC/SC/ST interchangeable port
Power Supply NiMH Rechargeable Battery/AC adapter
Battery Life 8 hours continuous operation, 20 hours standby (on one charge)
Operating Temperature (°C) -20~+50
Storage Temperature (°C) -40~+70
Relative Humidity 0~95% (non-condensing)
Dimensions (mm) 220(L) × 110(W) × 70(H)
Weight (kg) 1
Visual Fault Locator (VFL) Module1
Wavelength (±20nm) 650
Output Power (dBm) ≥-3
Max Measurement Range (km) 5
Optical Light Source Module1
Wavelength (±20nm) Same as OTDR working wavelength
Output Power (dBm) ≥-7
Optical Power Meter Module1
Calibrated Wavelength (nm) 850/1300/1310/1490/1550/1625
Measurement Range (dBm) -70~+6 (-60~+6 @ 850nm)
Detector Type InGaAs
Accuracy (nW) ± 5% ± 0.01 (±0.5dB@850nm)
PON Power Meter Module3
Calibrated Wavelength (nm) 1310 1490 1550
Measurement Range (dBm) -40~+8 -40~+8 -40~+20
Power Uncertainty (dB) ≤ 0.5
Display Resolution (dB) 0.01
Insertion Loss (dB) ≤ 1.5
Threshold 60
Data Storage 1200 records
MCI Optical Connector Inspector Module1
Zoom 250x
Resolution (um) 0.75
Focus Manual
Test Handle optional
Adapter 2.5mm universal UPC male and female, 1.25mm universal UPC male, LC/UPC female and other adapters (refer to optional accessories)
Link Image Software
Function Processing link image

  • Specifications describe the instrument’s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered.
  • The dynamic range is measured at maximum pulse width and averaging time of 3 minutes
  • Conditions for dead zone measurement: Reflection event is at 0.6Km, reflection intensity is less than -45dB; event dead zone is measured with pulse width of 10ns, attenuation dead zone is measured with pulse width of 30ns.
Note:
1. Visual fault locator, optical light source, optical power meter and MCI optical connector inspector modules are standard on “-H” high configuration models.
2. 1625nm can be replaced by 1650nm.
3. PON power meter module is standard on BL-OTDR5000-S1A-PON, BL-OTDR5000-S1A-PON-H, BL-OTDR5000-S3A-PON and BL-OTDR5000-S3A-PON-H.

Standard Accessories

No. Product Unit Quantity
1 BL-OTDR5000 Host set 1
2 FC Adapter piece 1
3 NiMH Rechargeable Battery piece 1
4 Power Adapter piece 1
5 USB Disk (User Manual) piece 1
6 USB Cable piece 1


Optional Accessories
No. Product Unit Quantity
1 SC Adapter piece 1
2 ST Adapter piece 1
3 MCI Test Handle piece 1
4 1.25mm Universal APC Male Adapter (Suitable for MCI Test Handle) piece 1
5 2.5mm Universal APC Male Adapter (Suitable for MCI Test Handle) piece 1
6 SC/APC Female Adapter (Suitable for MCI Test Handle) piece 1
7 FC/APC Female Adapter (Suitable for MCI Test Handle) piece 1
8 LC/APC Female Adapter (Suitable for MCI Test Handle) piece 1
9 Link Image Software piece 1


Ordering Information
Main Equipment Ordering Information:
Part number Product name Description
BL-OTDR5000-MA OTDR MM, wavelength: 850/1300nm, dynamic Range: 21/24dB, FC/UPC port
BL-OTDR5000-S2A OTDR SM, wavelength: 1310/1550nm, dynamic Range: 32/30dB, FC/UPC port
BL-OTDR5000-S2B OTDR SM, wavelength: 1310/1550nm, dynamic Range: 35/34dB, FC/UPC port
BL-OTDR5000-S2C OTDR SM, wavelength: 1310/1550nm, dynamic Range: 40/38dB, FC/UPC port
BL-OTDR5000-S2D OTDR SM, wavelength: 1310/1550nm, dynamic Range: 45/43dB, FC/UPC port
BL-OTDR5000-S2E OTDR SM, wavelength: 1310/1550nm, dynamic Range: 50/48dB, FC/UPC port
BL-OTDR5000-S3A OTDR SM, wavelength: 1310/1490/1550nm, dynamic Range: 38/37/37dB, FC/UPC port
BL-OTDR5000-S3B OTDR SM, wavelength: 1310/1550/1625nm, dynamic Range: 38/37/37dB, FC/UPC port
BL-OTDR5000-S1A-PON OTDR SM, wavelength: 1625nm, dynamic Range: 37dB, FC/UPC port; Build-in PON power meter
BL-OTDR5000-S3B-PON OTDR SM, wavelength: 1310/1550/1625nm, dynamic Range: 38/37/37dB, FC/UPC port; Build-in PON power meter
*High configuration (-H) series include visible fault locator, optical light source, optical power meter and MCI optical connector inspector modules
 
Optional Accessories Ordering Information:
Part number Product name Description
BL-OTDR5000-AD-SC Adapter SC adapter; Suitable for BL-OTDR5000 optical port
BL-OTDR5000-AD-ST Adapter ST adapter; Suitable for BL-OTDR5000 optical port
BL-OTDR5000-LIS Link Image Software Processing link image; Suitable for BL-OTDR5000
BL-OTDR5000-MCI-HD MCI Test Handle 2.5mm universal UPC male and female, 1.25mm universal UPC male, LC/UPC female and other adapters; Suitable for BL-OTDR5000-H high configuration series
BL-OTDR5000-MCI-A1.25-M Adapter 1.25mm universal APC male adapter; Suitable for BL-OTDR5000-MCI-HD test handle
BL-OTDR5000-MCI-A2.5-M Adapter 2.5mm universal APC male adapter; Suitable for BL-OTDR5000-MCI-HD test handle
BL-OTDR5000-MCI-ASC Adapter SC/APC female adapter; Suitable for BL-OTDR5000-MCI-HD test handle
BL-OTDR5000-MCI-AFC Adapter FC/APC female adapter; Suitable for BL-OTDR5000-MCI-HD test handle
BL-OTDR5000-MCI-ALC Adapter LC/APC female adapter; Suitable for BL-OTDR5000-MCI-HD test handle